Ruijie-Reyee RG-NIS-PA240-48 AC/DC 240W DIN-Rail Power Supply Module for Industrial Switch

Κατασκευαστής: Ruijie
Κωδικός Προϊόντος: REYE-0134
Διαθεσιμότητα: Please Login

The Ruijie-Reyee RG-NIS-PA240-48 is a DC power supply module that provides DC power input to one RG-NIS3100-8GT2SFP-HP or one RG-NIS3100-8GT4SFP-HP Industrial Switch. It supplies 48V/5A rated voltage to the system. The front panel has a three-pin power connector at the bottom for connecting a standard 10A power cord. The ADJ port is for outputs adjustable voltage from 48V to 53V based on adjustable resistance. DC OK Relay Contact: Rated: 30V at 1A, resistive load. The relay contacts are normally “ON” (closed) when the output (Vout) is greater than 90% of its rated value.

General Highlights:

  • Universal 85 - 264VAC or 120 - 370VDC lnput voltage
  • Accepts AC or DC input (dualuse of same terminal)
  • Built-in active PFC function
  • 150% peak load output for 3 seconds
  • Output short circuit , over-current , over-voltage, over-temperature protection
  • Safety according to lEC/UL/BS EN 62368
  • 3 Year Warranty

Specifications:

  • Rated Voltage Range: 100-240V, 50/60Hz
  • Max. Voltage Range: 85-264V, 47-63Hz
  • Max. Output Power: 240W
  • Ground-Leakage Current: ≤ 0.5mA
  • Operating Temperature: -40ºC to +70ºC
  • Storage Temperature: -40ºC to +85ºC
  • Storage Humidity: 20% RH to 95% RH (non-condensing)
  • Operating Humidity: Maximum: 90% RH (non-condensing)
  • Weight: 0.65 kg
  • Power Cord Specification: 10A power cord

Working Conditions:

Output power derating:

  • Operating temperature derating:
    –40ºC to –25ºC (–40°F to –13°F) Value: 3.34%/℃
    45ºC to 70ºC (113°F to 158°F), 115V AC to 164V AC input, Value: 2.0%/℃
    60ºC to 70ºC (140°F to 158°F), 230V AC to 264V AC input, Value: 2.5%/℃

Input voltage derating:

  • 85V AC to 100V AC, Value: 0.67%/V AC

Short circuit protection:

  • After the short circuit is eliminated, the power supply is restored within 10s
  • Hiccup mode:
    - Maintain constant current for 1s and power off for 10s to provide long-term short circuit protection and self-recovery

Overcurrent protection:

  • 230 V AC, rated load:
    - Ordinary temperature, high temperature: Value: 110%–200% Io, self-recovery
    - Low temperature: Value: ≥ 105%, full load after derating, self-recovery

Overvoltage protection:

  • 48 V:
    - Value: ≤ 60 V (hiccup, self-recovery after an exception is eliminated

Overtemperature protection:

  • 230 V AC, rated load, Value: 80ºC (176°F)
Χαρακτηριστικά
Κατασκευαστής Ruijie
Τύπος Προϊόντος Power Supply Unit
Mounting DIN Rail
Εγγύηση 3 Years

Σχετικά Προϊόντα (4)